DLSC-Y Series Thermal Imaging System
| Infrared Camera | DM66-37 (Water Proof Cover) | FOV/Min Focal Length | 25°×19°/0.3m |
| Spatial resolution | 0.65mrad | ||
| Type | Uncooled FPA | ||
| Spectral Range | 7.5-14μm | ||
| NETD | ≤0.06℃@30℃ | ||
| Frame Rate | 50Hz Analyzable heat map data output | ||
| Zoom | Electrical / Automatic | ||
| Temp Range | -20 ℃~+650 ℃, optional up to 1200℃ | ||
| Accuracy | ±2℃ or ±2% of reading (whichever is greater) | ||
| Mode | Auto | ||
| Atmospheric transmittance correction | Auto | ||
| Emissivity correction | Auto | ||
| Optical correction | Auto | ||
| Method | Continuous & Dynamic | ||
| Working Temp | -15℃~ +50℃ | ||
| Storage Temp | -40℃~70℃ | ||
| Protection Class | IP66 | ||
|
| |||
| Tripod | Gitzo GT2542 (3 long nails) | Bearing | 18KG |
| Closed length | 56cm | ||
| Max Height | 167cm | ||
| Max Height (Axis lay down) | 139cm | ||
| Min Height | 15cm | ||
|
| |||
| Main Control Box | Computer | Customized touch screen | |
| Communication module | 4G | ||
| Power | AC220V / DC12V Aviation plug | ||
| Protection class | IP66 | ||
| Basic analysis function | Spot (cross point display, Multipoint measurement); Linear analysis (Multi-line measurement)); Regional analysis (Multi-region measurement, Free to move and resize) | |
| Adjustment function | Automatically adjust image gain and brightness/contrast; Electric Focusing: Auto/Manual | |
| Basic setting function | High temperature alarm; high and low temperature capture; isothermal analysis; Pseudo-color function: setting function of emissivity, distance, ambient temperature, relative humidity and other parameters; freeze/activate function: image electronic zoom function | |
| Smart alarm function | Set alarm temperature value, the system will automatically send message to mobile phone | |
| Professional infrared analysis software | Multiple trend analysis | Automatic generation of dynamic infrared data lists, dynamic time-temperature curves, dynamic straight-to-temperature curves |
| Load data correlation function | The power equipment load value that can be marked at any moment is related to the trend curve | |
| Multi-analysis window display | Multiple object analysis windows can be displayed at the same time and switched quickly for easy comparison of different images | |
| File interception recording | A section of an intercepted file is rerecorded as a file | |
| Report generated automatically | Automatically generate reports based on analysis templates that have multiple analysis templates | |
| Key frame quick recall | Quickly retrieve key frames for any part of interest in the trend curve | |
| Data Extraction | Get infrared image or analysis object contains temperature data copied to excel | |
| Time temperature trend analysis | The trend curve of the maximum temperature, average temperature, and minimum temperature can be obtained to understand the temperature change of the entire load cycle | |
| Multiple analysis curves are displayed in the same coordinate system | Can compare the temperature difference between the concerned part and the normal part to judge the defect | |
| Straight line temperature trend curve | The trend curve of the temperature in the straight line range as the load or operating condition changes | |















